Top Quality ASTM F1554 Anchor Bolts Foundation Bolts for Detroit Factories
Short Description:
The ASTM F1554 specification covers anchor bolts designed to anchor structural supports to concrete foundations. F1554 anchor bolts can take the form of either headed bolts, straight rods, or bent anchor bolts. Thread Size: 1/4″-4″ with various lengths Grade: ASTM F1554 Grade 36, 55, 105 Various material grade and metric size are also available Finish: Plain, Black Oxide, Zinc Plated, Hot Dipped Galvanized, and so on. Packing: Bulk about 25 kgs each carton, 36 cartons each pallet....
Product Detail
Product Tags
Top Quality ASTM F1554 Anchor Bolts Foundation Bolts for Detroit Factories Detail:
The ASTM F1554 specification covers anchor bolts designed to anchor structural supports to concrete foundations.
F1554 anchor bolts can take the form of either headed bolts, straight rods, or bent anchor bolts.
Thread Size: 1/4″-4″ with various lengths
Grade: ASTM F1554 Grade 36, 55, 105
Various material grade and metric size are also available
Finish: Plain, Black Oxide, Zinc Plated, Hot Dipped Galvanized, and so on.
Packing: Bulk about 25 kgs each carton, 36 cartons each pallet. Or, comply with your requirement.
Advantage: High Quality and Strict Quality Control, Competitive price,Timely delivery; Technical support, Supply Test Reports
Please feel free to contact us for more details.
Product detail pictures:
We are committed to providing easy,time-saving and money-saving one-stop purchasing service of consumer for Top Quality ASTM F1554 Anchor Bolts Foundation Bolts for Detroit Factories, The product will supply to all over the world, such as: Thailand, Swedish, Portugal, Our company warmly invites domestic and overseas customers to come and negotiate business with us. Allow us to join hands to create a brilliant tomorrow! We've been looking forward to cooperating with you sincerely to achieve a win-win situation. We promise to try our best to deliver you with high quality and efficient services.
Departmental Procedures & Guidelines for Inspections, Certifications, Load Testing, Repairs & Painting of Fire Escapes
Inspections by Structural Engineers, Fire Escape Engineers or others acceptable to the Official:
In layman’s terms, the city official is looking for a registered structural engineer or others qualified and acceptable by the Fire/Code Official to do a Critical Examination in lieu of a Live Load Test (criteria submitted or discussed prior to inspection) and issues written verification and certification that all connections are free of internal rust or rot as well as all original hardware (square head bolts or rivet) are reinforced and or replaced in lieu of Live Load Test. All supports (thru-bolts or cemented) into the wall must be verified and certified in lieu of Live Load Test. A fire escape confidence test and tag must be submitted if fire escape passed. The report with photos identifying violations for repairs must include repair criteria submitted to the official for repair vendor to use as a guide during and with engineer oversight of permitted repairs. A Fire Escape Confidence Test and tags identifying certified condition are then submitted. Recommended cycle for live load testing is 20 yrs after total refurbishment or as required by official.
Repairs by Ornamental Ironworkers, Welding Companies or others acceptable to the Official:
In layman’s terms, the city official is looking for a qualified licensed repair vendor to do all work under repair permit (if required) with engineer oversight of repair criteria submitted for approval to the official in lieu of Live Load Test. All connections must be free of internal rust or rot, spot primed and sealed. All worn material repaired and or replaced. All supports into wall reinforced, repaired and certified in a Fire Escape Confidence Test. In lieu of Live Load Test, all square head bolts, rivets and or welded connections must be certified, reinforced and or replaced based on age or condition. All ladders and cantilevers must be balanced and drop 2-3 ft per second, hit the ground and stay down and must lead to a public way. All roof ladders must be secure. No full painting of any fire escape until all spot painted repairs are inspected and certified under engineer oversight and or city official permit sign-off. Full replacement is subject to permits and or possible code upgrade requirements.
Painting by EPA Licensed Renovators (if lead paint is present) or others acceptable to Official:
In layman’s terms, the city official is looking for a paint vendor (EPA Certified Renovator if required) to do all work as per EPA Guidelines due to the fact that all fire escapes older than 1978 are presumed to have lead (EPA) unless identified as no lead or low lead by a licensed lead inspector. Entire building will be notified with signage and all precautions shall be taken to collect paint chips at grade. No sandblasting or power assisted scraping without full fire escape encapsulation under EPA Guidelines. All major connection shall be sealed from water intrusion before during or after painting. All escapes should be spot painted every 3-5 yrs and fully painted every 5-10 yrs or as needed or ordered by a Fire/Code Official.
For more information please visit our website at https://fireescapeengineers.com or call 866-649-0333
Fire Escape Engineers is an approved member of the Fire Escape Services Network https://www.fireescpeservices.com and a founding member of the National Fire Escape Association (NFEA) https://www.nationalfireescapeassociation.org
Ty ren /Ty treo/ Thanh ren/Ty răng M6, M8, M10, M12, M16, M20- TCVN 197:2002/JIS B 1051 /DIN 975/DIN 976 (High quality Thread rod), Khớp nối ty ren (Thread rod coupling), Bịt đầu ty (Plastic end cap for thread rod), Tắc kê đạn (Drop in Anchor), Tắc kê tường (Anchor Bolts),
Ống ruột gà lõi thép có bọc nhựa phi 20/D20-Water-proof Flexible Metallic Conduit (W.PFMC); Ống ruột gà lõi thép không bọc nhựa- Flexible Metallic Conduit (FMC); Ống ruột gà lõi thép luồn dây điện có bọc nhựa dày- Liquidtight Flexible Metal Conduit (LFMC); Phụ kiện nối ống ruột gà lõi thép luồn dây điện-Flexible Conduit Connectors, Squeeze traight flexible connectors, Combination Flexible and IMC / EMT connectors.
Ống ruột gà lõi thép luồn dây điện AP-Ong ruot ga boc nhua phi 20/D20- Waterproof/Liquid tight Flexible Metallic Conduit
Tắc kê chuồn (Heavy duty concrete Insert), Cùm treo ống/Pad treo ống/ Đai treo ống 2 mảnh / Kẹp treo ty & ống / Kẹp treo ống thép luồn dây điện, ống PCCC/ HVAC (Steel conduit hanger/Steel conduit Clamp/Pipe hanger), Kẹp xà gồ/ Kẹp dầm thép (Beam Clamp/Iron Beam Clamp), Kẹp treo C (Purlin Clamp/Suspending Clamp), Kẹp treo ống HVAC (Clevis hanger), Kẹp treo ống & ty ren (K Clip), Kẹp treo dầm (Flange Clip), Kẹp treo Omega (Omega trap), Kẹp treo ống với kẹp C (Applicable hanger) Thanh chống đa năng (Unistrut Channel/ Strut/ C-Channel/ Double Unistrut profile ), Đai ốc lò xo cho thanh chống đa năng (Long spring nut), Tay đỡ đơn (Cantilever Arm), U cùm (U bolts), U bolt lá, Gía đỡ cơ điện M&E /HVAC/PCCC/ Kẹp treo ống thép/ Kẹp xà gồ -Fixings and Supports for Plumbing, Fire Protection, Heating, Ventilation and Air Conditioning- Mechanical Fixings, Fasteners and Spring steel Sprinkler Supports- Pipe & hanger clip- Pipe Clamp Miệng gió nhôm/Air Grille- Louver; Phụ kiện chống sét & nối đất- Lightning protection & grounding accessories; Thang cáp/ Máng cáp / Hộp cáp- Cable ladder/ Cable tray/ Trunking; galvanized steel tubing, conduit, tube, Electrical Conduit, electrical conduit, Electrical Metallic Tubing, EMT, Rigid Metal Conduit, Galvanized Rigid Steel Conduit, Galvanized Rigid Conduit, GRC, Intermediate Metal Conduit, IMC, conduit thin wall, conduit, Raceway, raceway, Electrical
CÔNG TY TNHH THIẾT BỊ ĐIỆN AP
22 Lê Văn Khương, xã Đông Thạnh, Huyện Hóc Môn, tp. Hồ Chí Minh
Tel : (84.8) 37115015 / (84.8) 37115430 – Fax : (84.8) 37115029
Sales Department
Tel: 0915 574 448
AP ELECTRICAL EQUIPMENT CO.,LTD
Wesite: www.giconduit.com / www.apelectric.com.vn