factory low price ASTM A325M 8S Heavy Hex Structural Bolts Export to Japan

factory low price ASTM A325M 8S Heavy Hex Structural Bolts Export to Japan

Short Description:

ASTM A325M 8S Metric Size Heavy Hex Structural Bolts The bolts are intended for use in structural connections. These connections are covered under the requirements of the Specification for Structural Joints Using ASTM A325 Bolts, approved by the Research Council on Structural Connections, endorsed by the American Institute of Steel Construction and by the Industrial Fastener Institute.   Dimension: ASME/ANSI B18.2.3.7M Thread Size: M12-M36 with various length Grade: ASTM A325M Type-1 Grade Ma...


Product Detail

Product Tags

We are proud of the superior customer gratification and wide acceptance due to our persistent pursuit of top of the range both of those on merchandise and service for A193 B7 Threaded Studs price, Step Down Studs price, A193 B7 Combination Studs to Irish, Our merchandise are widely recognized and trusted by users and can meet up with continuously changing economic and social needs.
factory low price ASTM A325M 8S Heavy Hex Structural Bolts Export to Japan Detail:

ASTM A325M 8S Metric Size Heavy Hex Structural Bolts

The bolts are intended for use in structural connections. These connections are covered under the requirements of the Specification for Structural Joints Using ASTM A325 Bolts, approved by the Research Council on Structural Connections, endorsed by the American Institute of Steel Construction and by the Industrial Fastener Institute.

 

Dimension: ASME/ANSI B18.2.3.7M

Thread Size: M12-M36 with various length

Grade: ASTM A325M Type-1

Grade Marking: A325M 8S

Finish: Black Oxide, Zinc Plating, Hot Dip Galvanized, Dacromet, and so on

Packing: Bulk about 25 kgs each carton, 36 cartons each pallet

 

Advantage: High Quality and Strict Quality Control, Competitive price,Timely delivery; Technical support, Supply Test Reports

Please feel free to contact us for more details.

 


Product detail pictures:

factory low price ASTM A325M 8S Heavy Hex Structural Bolts Export to Japan detail pictures


We always continually offer you by far the most conscientious customer service, and the widest variety of designs and styles with finest materials. These attempts include the availability of customized designs with speed and dispatch for factory low price ASTM A325M 8S Heavy Hex Structural Bolts Export to Japan, The product will supply to all over the world, such as: Paris, United States, Iceland, During the 10 years of operating, our company always try our best to bring consumption satisfaction for user, built a brand name for ourselves and a solid position in the international market with major partners come from many countries such as Germany, Israel, Ukraine, United Kingdom, Italy, Argentina, France, Brazil, and so on. Last but not least, price of our products are very suitable and have fairly high competition with other companies.



  • If your clothing is a frame for your face, from which the glory of God is to shine, it’s proper. If your clothing draws attention to your body, to outline it, to make it noticed, then it’s sensual.

    MP3: https://illbehonest.com/how-a-christian-woman-is-to-adorn-herself-paul-washer

    Full Sermon: https://illbehonest.com/recovering-biblical-womanhood-paul-washer



    Departmental Procedures & Guidelines for Inspections, Certifications, Load Testing, Repairs & Painting of Fire Escapes
    Inspections by Structural Engineers, Fire Escape Engineers or others acceptable to the Official:
    In layman’s terms, the city official is looking for a registered structural engineer or others qualified and acceptable by the Fire/Code Official to do a Critical Examination in lieu of a Live Load Test (criteria submitted or discussed prior to inspection) and issues written verification and certification that all connections are free of internal rust or rot as well as all original hardware (square head bolts or rivet) are reinforced and or replaced in lieu of Live Load Test. All supports (thru-bolts or cemented) into the wall must be verified and certified in lieu of Live Load Test. A fire escape confidence test and tag must be submitted if fire escape passed. The report with photos identifying violations for repairs must include repair criteria submitted to the official for repair vendor to use as a guide during and with engineer oversight of permitted repairs. A Fire Escape Confidence Test and tags identifying certified condition are then submitted. Recommended cycle for live load testing is 20 yrs after total refurbishment or as required by official.

    Repairs by Ornamental Ironworkers, Welding Companies or others acceptable to the Official:

    In layman’s terms, the city official is looking for a qualified licensed repair vendor to do all work under repair permit (if required) with engineer oversight of repair criteria submitted for approval to the official in lieu of Live Load Test. All connections must be free of internal rust or rot, spot primed and sealed. All worn material repaired and or replaced. All supports into wall reinforced, repaired and certified in a Fire Escape Confidence Test. In lieu of Live Load Test, all square head bolts, rivets and or welded connections must be certified, reinforced and or replaced based on age or condition. All ladders and cantilevers must be balanced and drop 2-3 ft per second, hit the ground and stay down and must lead to a public way. All roof ladders must be secure. No full painting of any fire escape until all spot painted repairs are inspected and certified under engineer oversight and or city official permit sign-off. Full replacement is subject to permits and or possible code upgrade requirements.
    Painting by EPA Licensed Renovators (if lead paint is present) or others acceptable to Official:
    In layman’s terms, the city official is looking for a paint vendor (EPA Certified Renovator if required) to do all work as per EPA Guidelines due to the fact that all fire escapes older than 1978 are presumed to have lead (EPA) unless identified as no lead or low lead by a licensed lead inspector. Entire building will be notified with signage and all precautions shall be taken to collect paint chips at grade. No sandblasting or power assisted scraping without full fire escape encapsulation under EPA Guidelines. All major connection shall be sealed from water intrusion before during or after painting. All escapes should be spot painted every 3-5 yrs and fully painted every 5-10 yrs or as needed or ordered by a Fire/Code Official.

    Related Products